Individuals can identify deluge systems, preaction systems, and their components. They can install and troubleshoot these systems. They understand sizing and installation requirements for standpipes. They know how to determine water supply requirements for systems. They can describe fire pump system components and are able to install, maintain, and troubleshoot fire pumps. They are familiar with application-specific sprinkler types and can select suitable sprinklers/nozzles for an application.
- Type Validation
- Time Hours
Skills
- Application-Specific Sprinklers
- Deluge Systems
- Firecycle® Systems
- Fire Department Connections
- Fire Pump Systems
- Hydrostatic Testing
- Inspection and Troubleshooting
- LINK-SEAL® Installations
- Preaction Systems
- Pumps and Drivers
- Standpipes
- Testing and Maintenance
- Water Chemistry
- Water Supplies